HPE Proliant DL360E G8

End of life Date:
August 16, 2021
OEM:
HPE
Type:
Server Computer

HP ProLiant DL360e Gen8 Server - Specifications:-

Physical specification

Specification Description

Dimensions (H x W x D) "8 SFF: 4.32 x 43.46 x 69.9 cm (1.7 x 17.1 x 27.5 in)

4 LFF: 4.32 x 43.46 x 75.0 cm (1.7 x 17.1 x 29.5 in)"

Weight (approximate) "Maximum (all hard drives, power supply, and processor installed):
8 SFF: 17.14 kg

4 LFF: 17.40 kg

Minimum (one hard drive, power supply, and processor installed):
8 SFF: 13.20 kg

4 LFF: 13.65 kg"

top

Electrical specifications

Specification Description

Rated line voltage 100 to 120 V ac

Rated input current 4.5 A (at 120 V ac) to 2.2 A (at 240 V ac)

Rated input frequency 50 to 60 Hz

BTU Rating maximum "1773 BTU/hr (at 120 V ac)

1715 BTU/hr (at 240 V ac)"

Power supply output (per power supply)

Rated Steady-State power "460 W (at 100 to 120 V ac)

460 W (at 200 to 240 V ac)

750 W (at 100 to 120 V ac)

750 W (at 200 to 240 V ac)"

Maximum peak power "460 W (at 100 to 120 V ac)

460 W (at 200 to 240 V ac)

750 W (at 100 to 120 V ac)

750 W (at 200 to 240 V ac)"

top

Environmental specifications

Specification Description

Operating temperature 10° to 35°C (50° to 95°F)

Non-operating temperature -30° to +60°C (-22° to +140°F)

Operating relative humidity 10% to 90%, non-condensing

Non-operating relative humidity 5% to 95%, non-condensing

Operating altitude 3048 m (10,000 ft)

Non-operating altitude 9144 m (30,000 ft)

Acoustic noise "Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle (1P non-redundant):
LWAd: 4.7 B

LpAm: 33 dBA

Operating:
LWAd: 4.7 B

LpAm: 33 dBA

Idle (2P redundant):
LWAd: 5.0 B

LpAm: 35 dBA

Operating:
LWAd: 5.0 B

LpAm: 35 dBA"

top

Safety certifications

Specification Description

FCC Rating Class A

Normative standards CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1